Uniaxial AS-active-probes

active, calibrated, pluggable Magnetic Field Probes

For measurement uniaxial probes are aligned with the magnetic field.

There are two types distinguished by measurement direction.

Transverse Probe

determination of polarity of a permanent magnet with transverse probe (south pole)

Axial Probe

determination of polarity of a permanent magnet with axial probe (south pole)

 

 

typical DC magnetic fields and corresponding AS-probes

The probes are categorized by sensitivity classes (de) and type of construction.

 

Overview uniaxial AS-active-probes

 

AS-probe axis maximum
measurement
range
temperature
range
dimension data sheet
AS-UAP GEO-X A 200 µT 50°C Ø 17.0 PDF Icon page 24
AS-UAP Lot A 200 µT 50°C Ø 18.8 PDF Icon page 25
AS-VTP T 20 mT 50°C 1.4 x 6 PDF Icon page 23
AS-LTM T 200 mT 50°C 1.4 x 5 PDF Icon page 21
AS-LAP A 200 mT 50°C Ø 6.0 PDF Icon page 22
AS-NTP 0,6 T 2000 mT 100°C 0.6 x 5 PDF Icon page 13
AS-NTP-Flex T 2000 mT 100°C 0.6 x 4 PDF Icon page 18
AS-NTP-Flex 0,6 T 2000 mT 150°C 0.6 x 5 PDF Icon page 19
AS-NTP-Hot-05 T 2000 mT 150°C 1.5 x 6 PDF Icon page 17
AS-NTM T 2000 mT 50°C 1.4 x 5 PDF Icon page 14
AS-NTM-2 T 2000 mT 50°C 1.4 x 5 PDF Icon page 15
AS-NCu-Wire T 2000 mT 100°C 0.6 x 3 PDF Icon page 20
AS-NAP A 2000 mT 50°C Ø 6.0 PDF Icon page 16
AS-HAP A 20 T 50°C Ø 6.0 PDF Icon page 12

 

Uniaxial Transverse Probes

Typical applications: air gaps, electric motors, relais.

 

AS-VTP

for small fields like e.g. residual magnetism
measurement range ±20 mT

AS-VTP: transverse magnetic field probe for small fields with probe carrier from glass-fiber reinforced plastic. The position of the active area is marked with a white dot.

 

AS-NTP 0,6

thin, stiff model; thickness 0.6mm

AS-NTP 0,6: transverse AS-active-probe with thin stiff probe carrier (thickness 0.6mm)

 

AS-NTP-Flex

thin, flexible model with ceramic element; thickness 0.6mm

AS-NTP-Flex: transverse AS-active-probe with flexible probe carrier and ceramic sensor

 

AS-NTP-Flex 0,6

thin, flexible model; thickness 0.6mm

AS-NTP-Flex 0,6: transversale AS-Aktivsonde mit flexiblem Sondenträger

 

AS-NTM

measurement range ±2000mT
robust model in brass profile
thickness 1.4mm

AS-Aktivsonde AS-NTM

 

AS-LTM

measurement range ±200mT
robust model in brass profile
thickness 1.4mm

AS-Aktivsonde AS-NTM

 

AS-NTM-2

high precision version
with 0.05% linearity error

AS-active-probe AS-NTM

 

AS-NTP-Hot-05

high temperatur range: from -40°C to +150°C

AS-NTP-Hot-05: transverse AS-active-probe for temperatur range -40°C to +150°C

 

AS-NCu-Wire

sensor on thin wires; thickness 0.6mm

AS-NCu-Wire; transverse magnetic field probe with ceramic sensor on thin wires

 

 

Uniaxial Axial Probes

Typical applications: air-core coils, large surfaces

 

AS-HAP

measurement range ±20T; diameter 6mm

AS-NAP: axiale AS-Aktivsonde

 

AS-NAP

measurement range ±2000mT; diameter 6mm

AS-NAP: axiale AS-Aktivsonde

 

AS-LAP

measurement range ±200mT; diameter 6mm

AS-NAP: axiale AS-Aktivsonde

 

 

AS-UAP GEO-X

Earth magnetic field; measurement range ±200µT

AS-UAP GEO-X: axiale AS-Aktivsonde für das Erdmagnetfeld bis ±200µT

 

 

AS-UAP Lot

Plumb bob model with weighted tip for measuring the vertical component of the earth’s magnetic field;
measurement range: ±200µT

AS-UAPLot: axiale AS-Aktivsonde in Lotform für das Erdmagnetfeld bis ±200µT


Application of Uniaxial AS-active-probes

 

with Teslameter FM 302, USB-connector and analog output

Verwendung der AS-Aktivsonden mit dem Teslameter FM 302

 

with AS-Probe Adapter

Verwendung der AS-Aktivsonden mit dem AS-Sonden Adapter

 

with AS-Adapter 3

connection diagram of usage AS-Adapter 3 with three single-axis magnetic field probes, connect probes with three adapter cables, connection to PLC and oscilloscope

as stand-alone transducer

Verwendung der AS-Aktivsonden einzeln als autonomer Messwandler


Downloads

Operating Manuals

PDF Icon Operating manual